PENTAIR CLEAN & CLEAR
FEATURES - NSF listed
- Unionized connections
- Integrated continuous High Flow™ Internal Air Relief
- Chemical resistant tank body
- Lock ring with spring-loaded safety latches
- Coreless cartridge for easy cleaning
- High Flow manual air relief valve
- 1 in. drain and wash out
- Single piece base and body design
Filter Installation
- The Clean and Clear Plus Cartidge Filter should be mounted on a level concrete slab. Positionthe filter so that instructions, warnings and the pressure gauge are visible to the operator. It also should be positioned so that the piping connections, control valve and drain port are convenient and accessible for servicing and winterizing
- Be certain to install electrical controls(e.g on/off switches, timers,control systems,etc) at least five (5) feet from the filter. This permits one to stand clear of the filter during system start up
- Allow sufficient clearance around the filter to permit visual verification that the clamp is properly installed around the tank flanges.
- Allow sufficient space above the filter to remove the filter lid for cleaning and servicing. This distance will vary with the model of filter you are using. See Table 1 for the required vertical clearance.
- Position the filter to safely direct water drainage. Rotate the High Flow™ Manual Air Relief Valve to safely direct purged air or water. Water discharged from an improperly positioned filter or valve can create an electrical hazard as well as damage property.