FEATURES
- Proprietary software designed to help detect a suction or drain blockage, automatically stopping the pump
- Compliant with the current ASME A112.19.17 standard for Safety Vacuum Release Systems (SVRS)
- Eight (8) programmable speed settings and built-in timer
- New rotatable keypad for easy programming and viewing – keypad has the ability to be wall mounted with optional wall mount kit(sold separately)
- Totally enclosed-fan cooled design (TEFC) for quiet operation
- ENERGY STAR ® Certified
Motor Features
- Permanent Magnet Synchronous Motor (PMSM)
- High efficiency
- Superior speed control
- Operates at lower temperatures due to high efficiency
- Same technology as deployed in hybrid electric vehicles
- Designed to withstand outdoor environment
- Totally enclosed fan cooled
- Three-phase motor
- 56 Square Flange
- Six-Pole
- Low noise
Pump Operating Modes
The IntelliFlo® VS+SVRS Pump can be programmed three ways:
- Manual Operation:Speed buttons 1-4 can be programmed for manual operation. This means the speed button is pressed and then the start button and the pump runs a programmed speed. Speeds 5-8 can not be programmed for manual operation because there are not buttons associated with them.
To operate the pump in Manual mode, press one of the four speed buttons, and press the Start/Stop button to run the assigned speed for that button. When the pump is running a Manual Speed Setting (Speed 1,2,3 or 4 button pressed manually) and a scheduled speed is set to run, the scheduled Speed’s time is over, it will not revert back to the manually pressed speed. If the pump is running a schedule and a speed button is pressed manually, the pump will run the manually selected speed until next scheduled speed program. - Egg Timer (Duration): Speeds 1-4 can be programmed to run for a duration of time once pressed. This means tyhat the Speed button is pressed and then the start button and the pump runs a programmed speed and the speed will turn off at the end of a preprogrammed amount of time. Speeds 5-8 have no direct pump speed buttons and therefore cannot be programmed with an Egg-Timer.
- Schedule: The spped button can be programmed to turn on and off at a cretain time. The LED above the Start/Stop button must be lit for the pump to run schedules. When a speed is set to run in Schedule mode it can still be operated manually. When a speed is programmed to run 23 hopurs and 59 minutes per day it will not turn off. For example, for the pump to run 24 hours per day, program the pump ro start at 8:00AM and stop at 7:59 AM.