PENTAIR TA TAGELUS
FEATURES
- ABS body
- Large, one-piece handle for trouble free operation
- Six-position, positive-lock operation
- Heavy-duty diverter
- Special winterizing position
VALVE: POSITIONS:
FILTER – From Pump, through valve downward THRU
FILTER up through center pipe to valve RETURN port for normal filter action and
vacuuming pool thru filter.
BACKWASH – From pump through valve, down through center pipe and to valve WASTE port for
cleaning filter by reversing flow.
RINSE – From pump, through valve downward up through filter up through center pipe to
valve WASTE Port for start-up cleaning and resetting filter bed after back-washing.
WASTE – From pump through valve BY PASSES FILTER and goes to WASTE port for vacuuming
directly to waste, lowering pool level, or draining pool.
CLOSED NO FLOW – DO NOT USE THIS SETTING WITH PUMP OPERATING.
RECIRCULATE – From pump, through valve, bypasses filter and goes to return port for circulating water without going thru filter.
VALVE CARE
The valve is a very important part ot’ your pool equipment and
inst;lllation. Proper care and maintenanre, will add many years of
service and cnjoymcnt to thc pool. Follow these suyyc%stions for long
troul~l(s free operation.
- to clean the exterior of the valve of dust and dirt, wash with a mild
detergent and water and then hose off.Do not use solvents. - The valve clamp used on your valve has been manufactured with high quality errosion resistant materials.The manufacturing process could allow sharp edges to be present on the parts. When working in and around the clamp use caution to prevent potential injury to fingers or hands from contact with sharp edges.
- Your valve is a pressure vessel and should never be serviced while under pressure. Always relieve tank pressure and open air bleeder before attempting to service your valve.
- Open the manual air bleeder and stand clear of the filter/valve before restarting your pump